The BIOFLOAT™ 96-well plate F Bottom outperforms existing products by its anti-adhesive properties
Ready-to-use for spheroid cell culture
The BIOFLOAT™ 96-well plate provides a highly defined, fully inert, and cell-repelling surface.
Product Characteristcs
Plate color: clear
Well bottom: Flat (F – bottom)
Well volume: 390 µl
Dimensions: 85.20 mm (width) x 16.55 mm (height) x 127.80 mm (length)
Material: Polystyrene (PS)
Sterile: yes
Made in Germany
Quantity: single
Product Characteristcs
Plate color: clear
Well bottom: round (U – bottom)
Well volume: 310 µl
Dimensions: 85.20 mm (width) x 16.55 mm (height) x 127.80 mm (length)
Material: Polystyrene (PS)
Temperature range: – 20 °C to + 50 °C
Sterile: yes
Made in Germany
Quantity: bag of 4 plates with resealable snap lock
Ready-to-use for spheroid cell culture
The BIOFLOAT™ 96-well plate provides a highly defined, fully inert, and cell-repelling surface.
Product Characteristcs
Plate color: clear
Well bottom: round (U – bottom)
Well volume: 310 µl
Dimensions: 85.20 mm (width) x 16.55 mm (height) x 127.80 mm (length)
Material: Polystyrene (PS)
Temperature range: – 20 °C to + 50 °C
Sterile: yes
Made in Germany
Quantity: bag of 4 plates with resealable snap lock
Want to make sure BIOFLOAT™ 96-well F bottom is suitable for your cell culture?
We are confident in the quality of our products and you can also be convinced of this.
We invite you to try our 96-well plates to get perfect spheroids and organoids for your application.
The reliable quality of the BIOFLOAT™ cell culture surface enables the formation of perfect spheroids even for challenging cells. This also includes cells that do not form spheroids on existing products.
Cardiac myocytes
Endothelial cells
Primary hepatocytes
Alveolar epithelial cells
Neuronal stem cells
Cardiac myocytes
Endothelial cells
Primary hepatocytes
Alveolar epithelial cells
Neuronal stem cells
Fibroblasts (M. musculus) Squamous cell cancer cell line (H. sapiens) Melanoma cell line (M. musculus) Colon carcinoma cell line (H. sapiens, Caucasian) Pancreatic adenoma cancer cell line (H. sapiens) Ovarian cell line (C. griseus) Epithelial breast cancer cell line (stem cell-like) (H. sapiens) Tumourigenic breast epithelial stem cell line from D492 cells (H. sapiens) Pancreatic cancer cell line (H. sapiens) Embryonic stem cells (S. scrofa domesticus) Pancreatic adenoma cancer cell line (H. sapiens) Lung adenocarcinoma cell line (H. sapiens) Breast cancer cell line (H. sapiens) Colon cancer cell line (H. sapiens) Primary dental pulp stem cells (H. sapiens) Pancreatic cancer cell line (H. sapiens) | Immortalised osteoblasts (H. sapiens) Venous endothelial cells (H. sapiens) iPSC-derived hepatocytes Breast cancer cell line (H. sapiens) Pancreatic cell line (H. sapiens) Hepatic stellate cells/Ito cells (F norwegicus) Hepatic stellate cells/to calls (r. Sapiens) B-lymphocyte cell line from myeloma patients Immortalised astrocytes (H. sapiens) Differentiated fatty cell organoids from pluripotent stem cells Endometrial organoids from detached primary cells (non-human primates) Fibroblast progenitor cells (M. cerebralis) IPSC-derived cardiomyocytes (H. sapiens) Liver organoids (differentiated) (M. musculus) Neuronal stem cells (HN9 differentiated) Primary hepatocytes (H. sapiens, M. musculus, M. fascicularis, C. lupus famillaris) |
Raw Material Processing
The product does not use any rawmaterials of animal
or biological origin and therefore does not have TSE/BSE.
The polymer raw materials used for coating plates were positively evaluated
for quality consistency using GPC, GC-MS and NMR spectroscopy.
The sterile, non-pyrogenic/endotoxin-free, non-cytotoxic, DNase-/RNase-/DNA-free multi-well plates were coated using pipetting robots.
Coated plates were sterilized by electron beam irradiation according to DIN EN ISO 11137
Want to create perfect uniform spheroids?
Rapid spheroid formation
Shorten your experiment timelines. Single spheroids form faster on BIOFLOATTM surfaces than on most other ultra-low attachment surfaces.
Round and Uniform
The 3D cell culture and maintenance on the BIOFLOAT™ surfaces result in highly uniform spheroids and perfect data consistency. Cell satellites and irregular aggregations are eliminated.
Reliable spheroid culture
The reliable quality of the BIOFLOAT™ surface makes it a premium product for spheroid and organoid culture, including cells which fail to generate spheroids on existing products.
The BIOFLOAT™ is trusted by leading Pharma and R&D Institutions
Safe checkout
Product in stock
Fast shipping
Easy tracking
Why use BIOFLOAT™ coating technology for your research?
BIOFLOAT™ coating technology provides a highly defined, fully inert cell- and protein-repellent surface for cell culture labware and devices. Compact and reproducible spheroids are rapidly generated on BIOFLOAT™ coated surfaces, even with challenging cell types. Sticky proteins are inhibited to adsorb to your cell culture labware.
Which cells are compatible with the BIOFLOAT™ coating technology?
BIOFLOAT™ coating technology is compatible with broad range of human and animal derived cell lines or primary cells. This new technology is developed to generate cell spheroids; therefore, any cell line can be used which are known to form such spheroids or you can develop new organoid models containing spheroids with cell lines of your choice. In Tab. 1 you can find a selected number of cell lines cultured with BIOFLOAT™ coating technology.
Tab. 1 List of cell lines
Which products are available with the BIOFLOAT™ coating technology?
Choose between the ready-to-use 96-well plate, 384-well plate or DIY BIOFLOAT™ FLEX coating solution to modify a broad range of plastic and glass surfaces.
Does the coating react with chemicals?
All BIOFLOAT™ products do not contain any reactive groups, which can react with other chemicals.